Sentinel Microcell® (BunStock)
Physical Properties of Microcell
Closed-Cell Crosslinked Polyethylene Foam
| Typical PROPERTIES |
TEST
Procedure |
MC 1900 |
MC 2900 |
MC 3800 |
| DENSITY (PCF) |
ASTM
D-3575 |
2 |
3 |
4 |
| TENSILE STRENGTH (PSI) |
ASTM D-3575 |
40 |
60 |
90 |
| ELONGATION % |
ASTM
D-3575 |
135 |
150 |
150 |
| COMPRESSION RESISTANCE
(DEFLECTION) (PSI 25% COMPRESSION) (PSI 50% COMPRESSION) |
ASTM D-3575 |
8.5 16 |
16 25 |
20 32 |
| COMPRESSION
SET (50%)
(% ORIGINAL THICKNESS) |
ASTM D-3575 |
15 |
10 |
8 |
| TEAR RESISTANCE (PLI) |
ASTM D-3575 |
7 |
10 |
17 |
| Durometer 00 |
ASTM 2240 |
48 |
55 |
65 |
| THERMAL Stability
(% LINEAR SHRINKAGE @ 200 DEG. F. FOR 24 Hrs. |
|
<2% |
<2% |
<2% |
| WATER Absorption
(LBs./SQ. FT. CUT SURFACE) |
ASTM D-1667 |
Mix.
0.05 |
Max.
0.05 |
Max.
0.05 |
| CELL SIZE MODE |
Millimeters |
0.15 |
0.15 |
0.15 |
NOTE
Physical Properties listed are Nominal.
Specific Ranges and Tolerances for any individual application are available upon written request.
Because we cannot anticipate or control the many different conditions under which this information and our products may be used, we do not guarantee the applicability or the accuracy of this information or the suitability of our products for any specific application. Users of our products should make their own tests to determine the suitability of each product for their particular application. The products discussed are sold without warranty either expressed or implied. The buyer assumes all the responsibility for loss or damage arising from the handling and use of our products whether done in accordance with the directions or not. Statements concerning the possible use of our products are not intended as reccomendations to use our products in the infringement of any patent.
Sentinel Products Corp.
Crosslinked Polyethylene Foam & Rubber Products
70 Airport Road, P.O. Box S Hyannis, MA 02601 • 508-775-5220 • FAX: 508-771-1554